Error Number: 10025


Error Message:

HARDWARE: DPE LCA's not configured at startup


Applies to:

  • All

Service Information:

The Xilinx LCA's on the DPE were not loaded on startup. They are normally loaded using a file stored in the code bank. To determine if this file is corrupted or missing, use the "fw dir" command. Look for the entries labelled "DPE LCA". If there, look under the "Chksum" column for either "PASS" or "FAIL". If it says FAIL, or if no DPE entry is there, the code bank must be programmed again. If the DPE entry PASS'es, the incorrect firmware file may have been loaded, or the DPE LCA's may be faulty.


Operator Action:

Record error message and contact Creo Service


Cause:

  • Firmware has been corrupted.
  • Incorrect or incomplete firmware installed.
  • Faulty DPE LCA's

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page