Error Number: 10051


Error Message:

HARDWARE: DPE failure - dpath control write = <hex data>, read = <hex data>


Applies to:

  • All

Service Information:

The DPE's datapath control register is tested at the beginning of every plot. This message reports that the contents of this register just before plotting were different than what was written to the register during plot initialization. Although this test was originally implemented to find a possible DPE bug, it now much more likely indicates a firmware bug, where the dpath control register is being setup a plot time with different parameters from plot initialization.


Operator Action:

Record error message and contact Creo Service


Cause:

  • Firmware bug
  • DPE is faulty

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page