Error Number: 10061


Error Message:

HARDWARE: External Debris Blower Filters Full


Applies to:

  • All

Service Information:

The debris cabinet is reporting that the filters are full. Check the filters, and replace as necessary.

If the filter looks fine, check the sensor inside the cabinet, and the cable running to the device.


Operator Action:

The device thinks the debris filter inside the debris cabinet is full. Open the cover of the cabinet and replace the filter. If the problem comes back, contact the CreoScitex Response Centre.


Cause:

  • Filter is full.
  • Faulty cable from debris cabinet to device.
  • Faulty sensor inside debris cabinet.

See Also:

  • Command: dr

Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:30 2002 PST