Error Number: 13018


Error Message:

EHBOOT: incorrect version length


Applies to:

  • All

Service Information:

The head is not responding correctly to a programming command. Check the head and MPE firmware release notes for any version incompatibilities.

Check the EH-BP cable and the head's power supplies.

The recorder should be reset and the command sequence re-attempted. If the error persists, the head's digital electronics may be faulty.


Operator Action:

Record error message and contact Creo Service


Cause:

  • Head and MPE firmware version incompatibilities.
  • EH-BP cable faulty
  • Head power supplies faulty
  • Head digital electronics faulty

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:34 2002 PST