Error Message: |
SAT: <Satellite Board> Error: <Output Name> |
Applies to: |
|
Service Information: |
The satellite driver detected an error when turning the indicated output on or off. Some satellite outputs can detect whether current is flowing through a device when it's turned on, and return an error when no current flows. The cable from the satellite board to the indicated device should be checked. This cable or the device should be replaced if necessary. If this doesn't help, the satellite board should be replaced. If this error happens intermittently, it may be due to internal electrical noise. Contact the TTE or factory integrators for more advice. This error message can be disabled temporarily be setting one of the following parameters to 0: "set sat luec 0" - for load/unload board errors "set sat cbec 0" - for cassette bay board errors "set sat ppec 0" - for plate picker board errors "set sat pdec 0" - for power distribution board errors |
Operator Action: |
Click on "Resume" if possible. The Platesetter may recover automatically. Even if it does, report this error message to Creo Service. |
Cause:
|
See Also: |
|
Go to CTP Firmware Error Index Page