Error Number: 14102


Error Message:

SAT: LUE Analog testpoint exceeded allowed minimum


Applies to:

  • All

Service Information:

The analog testpoint feature is normally disabled. If this feature has not been explicitly enabled, this error indicates a firmware bug. Otherwise, the voltage applied to the LUE analog testpoint is below the value set by the "set sat ltpmin" parameter. This parameter is normally set to its minimum value of 0.


Operator Action:

Record error message and call Creo Service.


Cause:

  • Possible firmware bug.
  • LUE analog testpoint voltage is below the value set by the "set sat ltpmin" parameter

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:35 2002 PST