Error Number: 14103


Error Message:

SAT: Engine Frame temperature out of range


Applies to:

  • All

Service Information:

The measured engine frame temperature is outside the range of reasonable values. This is likely due to a disconnected or faulty sensor. If these seem fine, the LUE may be faulty.

Note that faulty temperature readings will result in incorrect plate geometry!

This error message can be temporarily disabled by with "set sat et 0".


Operator Action:

Record error message and call Creo Service.


Cause:

  • Faulty engine frame temperature sensor or cable.
  • Faulty LUE

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:35 2002 PST