Error Number: 15053


Error Message:

ALE: Autoloader operation aborted


Applies to:

  • Platesetter_3244
  • Trendsetter_400/800_Auto

Service Information:

Trendsetter: If the terminal is running capture the last events and forward the file to firmware owner at Creo Vancouver. This is a firmware bug, and should never be reported.

Platesetter_3244: Job aborted from workstation.


Operator Action:

Trendsetter: Select resume if that option is available. If the error persists, try powering the machine off and back on again. If the problem still persists, call Creo service.

Platesetter_3244: None


Cause:

  • Trendsetter: This error is caused by a firmware fault. It is used for internal messaging, and should never be reported. Please report this error to the firmware designer. It would be very useful to know what conditions caused this error to occur and even more useful to have a diagnostic monitor log file. If possible, the 'verbose alcmd' setting should be 1 when generating the log file. Platesetter_3244: al_abort_before_grab flag was set in schedal from the workstation, this will cause the pick command to abort the pick if the plate has not yet been removed from the box.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:35 2002 PST