Error Number: 15079


Error Message:

ALE: timeout moving leading edge cylinder


Applies to:

  • All

Service Information:

Check for faulty LEC sensors by using the "lec" command from the diagnostic. If the sensor is faulty, use "set al le 0" or "set al les 0" to bypass the sensor and get the customer going. Arrange for field service. If the sensor is OK, test the LEC actuator by using "lec on" or "lec off" and see if any motion occurs.


Operator Action:

Clear obstruction near LEC actuator and select RESUME.


Cause:

  • Faulty LEC sensor
  • Faulty LEC actuator

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:36 2002 PST