Error Number: 15150


Error Message:

ALE: picker command timed out


Applies to:

  • Platesetter_3244

Service Information:

warm reset. basically the communications handshake to a stepper has most probably hung up. CY545 controller is on the ALE board, and communications is from the MPE via the back plane to the ALE. This should have nothing to do with the HV 80V or stepper driver.


Operator Action:

Reset machine.


Cause:

  • A communication to the CY545 stepper controller to setup the speed failed to complete.
  • A communication to the CY545 stepper controller to read the speed failed to complete.
  • A communication to the CY545 stepper controller to setup the position failed to complete.
  • A communication to the CY545 stepper controller to read the position failed to complete.
  • A communication to the CY545 stepper controller to move to an absolute position failed to complete.
  • A communication to the CY545 stepper controller to jog a relative number of steps failed to complete.
  • A communication to the CY545 stepper controller to move to home failed to complete.

See Also:

  • Command: PY
  • Command: PZ

Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:36 2002 PST