Error Number: 15213


Error Message:

ALE: error occured on previous plate, check if processor is ready.


Applies to:

  • Platesetter_3244

Service Information:

Check processor handshake status using "processor" command. Check conveyer interface board cabling. Check correct pcode and processor are set up in media #


Operator Action:

Check processor and resume.


Cause:

  • This error is reported if the processor plate_loc status is error(5) or unknown(6), or the plate_loc processor media is wrong, or processor is showing either not ready or fault.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:38 2002 PST