Error Number: 15222


Error Message:

ALE: remove plate from load ramp (wrong size)


Applies to:

  • Platesetter_3244

Service Information:

After winding the plate almost all the way onto the drum, but leaving the lower load ramp sensor covered, the load ramp sensor is checked. If no plate is sensed then the plate is presumably too small. It will then unwind the plate and release the LEC and roller for the operator to remove the plate.


Operator Action:

Lift brige and open front panel, remove plate from load ramp, select resume or cancel.

Check plate main scan size that is loaded into the bay.


Cause:

  • Plate was slightly smaller than expected.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:38 2002 PST