Error Message: |
ALE: Separator timed out moving out |
Applies to: |
|
Operator Action: |
Select the RESUME button on the workstation dialog box. If this fails to correct the problem, open the plate cover and inspect the plate separator arms and associated microswitches. The separator arms should be in their outboard position and the microswitches should be tripped. If everything looks normal, then Creo Service should be called. |
Service Information: |
At least one of the plate separator arms failed to trip the microswitch sensor while moving to the outboard position within the timeout specified by the aldly sio parameter. The sensor status may be checked by using the PICKER command. The sensor status should read TRUE if the separator arms are in their outboard position. The microswitches are wired in series, so both of them need to be tripped for the status to read TRUE. It may be useful to cycle the Separator Arms a few times using remote diagnostics. Older Autoloaders may experience a buildup of air pressure in the Separator Arm cylinders if they are extended for a long period of time. This causes the Separator Arms to stick in the inboard position. When the arms move to the out/home position, they move at an excessive speed and bounce off of the micro switch and hang up on the micro switch bracket. Cycling the Separator Arms will relieve this buildup of pressure for a short period of time. It may be useful to set the 'verbose alcmd' parameter to 1 in order to obtain further diagnostic information. Typing "ALE" will display the system air pressure. |
Cause:
|
See Also: |