Error Message: |
ALE: STEP : axis 2 distance out of range |
Applies to: |
|
Operator Action: |
This error should not occur during normal machine operation. If it does, first try selecting the RESUME button on the workstation dialog box a few times. If this does not make the problem go away, then select RESET PLATESETTER RECORDER from the workstation SYSTEM pull-down menu. If the problem persists, then Creo Service should be called. |
Service Information: |
This error occurs if a TABLE MOVE or TABLE JOG command is issued from the diagnostic monitor with a distance parameter that exceeds the maximum stepper travel limit specified by the aldrv 2 limit parameter. This error should not occur during normal machine operation. |
Cause:
|
See Also: |
|
Go to CTP Firmware Error Index Page