Error Message: |
ALE: Punch reported mechanical error: plate still in punch Punch reported mechanical error: problem moving punch inlay Punch reported mechanical error: problem moving punch stop Punch reported mechanical error: problem raising or lowering punch inlay Punch reported mechanical error: problem with punch plate sensor Punch reported mechanical error: punch could not find plate edge |
Applies to: |
|
Operator Action: |
Remove the plate from the machine and select "PLATE CLEARED" button on the workstation dialog box. Call Creo Service. |
Service Information: |
Either a mechanical movement in the punch is not being performed properly, the punch parameters are not set properly, or the plate is not being pushed into the punch correctly. Check for error messages on the punch display keypad. Watch the process/punching sequence to see where the error occurs. Check for the plate sticking on the table, or being skewed by the traveler. Check that the correct punch configuration is being used. It may be useful to set the 'verbose alconv' parameter to 1 in order to obtain further diagnostic information. |
Cause:
|
See Also: |
|