Error Number: 15350


Error Message:

ALE: STEP : axis 1 communication error


Applies to:

  • Trendsetter_400/800_Proofing

Operator Action:

Select RESUME from the workstation dialog box. If that doesn't correct the problem, then select RESET TRENDSETTER from the workstation TRENDSETTER pull-down menu. If the problem persists, call Creo service.


Service Information:

Try cycling power on the machine. Check the SPI and TEE boards and replace them if necessary. If problem recurs, call proofer TTE.


Cause:

  • An error occurred while communicating with the VR stepper controller. A hardware fault likely caused this.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:41 2002 PST