Error Number: 15351


Error Message:

ALE: STEP : axis 1 is busy


Applies to:

  • Trendsetter_400/800_Proofing

Operator Action:

Select RESUME from the workstation dialog box. If that doesn't correct the problem, then select RESET TRENDSETTER from the workstation TRENDSETTER pull-down menu. If the problem persists, call Creo service.


Service Information:

Try a "step 1 init" from the diagnostic terminal. If that doesn't correct the problem, reset the machine. Check the SPI and TEE boards, and replace them if necessary. If problem persists, call proofer TTE.


Cause:

  • An error occurred while writing to the VR stepper controller. This error is probably due to a hardware fault, or the issuing of a diagnostic command while the step axis is already in use.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:41 2002 PST