Error Number: 15528


Error Message:

ALE: %s %d timed out while aborting


Applies to:

  • Trendsetter_VLF
  • Platesetter_VLF

Service Information:

This error will be displayed if when the firmware is trying to stop a step motor axis it takes longer that the value specified by the nvs parameter "altim abort_timeout (abort)".


Operator Action:


Cause:

  • The value of the nvs "altim abort_timeout" may not be set correctly.
  • The communication between the MPE board and the stepper controller is broken so that the firmware does not detect that the motor is stopped.
  • Something is preventing the stepper motor from stopping.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page