Error Number: 15554


Error Message:

ALE: timeout moving balance weight actuator


Applies to:

  • Platesetter_VLF
  • Trendsetter_VLF

Service Information:

Check for a low value of the nvs parameter 'altim bwt' (balance cylinder timeout). Verify that the balance cylinder extended/retracted sensors are working properly, and check the wiring/plumbing. NOTE: This error is obsolete in VLF trendsetter version 1.40 and newer.


Operator Action:

This is not an operator serviceable error. Press resume or reset the machine to continue production. Call CreoScitex response center.


Cause:

  • A command to move the balance cylinders to the extended or retracted position timed out, either because the timeout was too small, a failure moving the actuator, or a failed sensor.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:43 2002 PST