Error Number: 15555


Error Message:

ALE: unable to detect balance weight %d


Applies to:

  • Platesetter_VLF
  • Trendsetter_VLF

Service Information:

Check for a low value of the NVS parameter "altim bwst" (balance find timeout). Verify that sensors are working properly NOTE: This error is obsolete in VLF trendsetter version 1.40 and newer.


Operator Action:

This is not an operator serviceable error. Press resume or reset the machine to continue production. Call CreoScitex response center.


Cause:

  • The firmware was unable to detect the balance weight. The timeout may be too short or the balance weight sensor could have failed.

See Also: