Error Number: 15621


Error Message:

ALE: no plate on unload X-axis or low vac, can't continue


Applies to:

  • Platesetter_VLF

Service Information:

The machine was expecting a plate on the unload x-axis table but it did not detect one. To verify that there is a plate on the unload table, the system polls the vacuum sensor until either vacuum reads higher than threshold or a timer expires. If the vacuum is less than the set threshold then, the system will issue this error.


Operator Action:


Cause:

  • Verify that the NVS parameter vac_threshold_x for the threshold is set to the appropriate value
  • Verify that the suction cups are place at the right location to grab a plate
  • Verify that the suction cups are in good condition
  • There may be a problem with the air pressure system

See Also: