Error Number: 15647


Error Message:

ALE: picker Y-axis not AWAY


Applies to:

  • Platesetter_VLF

Service Information:

Picker Y-axis was sent to the away position but the away sensor does not detect the tab.


Operator Action:


Cause:

  • The picker stoppers may not be far enough preventing the picker from reaching its destination.
  • The nvs parameter "step 4 away_limit" may be too small preventing the picker from reaching its position.
  • The picker home/away board may not be working properly.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:45 2002 PST