Error Number: 15687


Error Message:

ALE: balance weights not detected. Confirm position


Applies to:

  • Platesetter_VLF
  • Trendsetter_VLF

Service Information:

Check for valid NVS parameter wp1/wp2 'set state al wp1|wp2' (weight position 1|2). Reset to zero and run 'bal find' command. Check sensors. NOTE: This error is obsolete in VLF trendsetter version 1.40 and newer.


Operator Action:

This is not an operator serviceable error. Press resume or reset the machine to continue production. Call CreoScitex response center.


Cause:

  • The firmware was unable to detect one or both of the balance weights. This could be caused by a corruption of the saved NVS parameter weight positions (wp1/wp2) or failed balance weight sensors.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page