Error Number: 15688


Error Message:

ALE: plate length wrong. Remove plate from load table and configure bay


Applies to:

  • Platesetter_VLF

Service Information:

Check for messages in diagnostics regarding the plate. These messages begin with "Warning:" and should indicate the problem that is causing this error. The measured plate size and its error are also reported.


Operator Action:

Manually remove plate and confirm through workstation. Ensure that the plate dimensions match those configured for the workstation.


Cause:

  • During loading of the plate onto the load table, the mainscan size of the plate is measured. If the plate is not within nvs.cfg.load.plate_length_tol, this error is generated.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:46 2002 PST