Error Number: 16013


Error Message:

IMAGE: Specified \"around drum\" image size too large


Applies to:

  • All

Service Information:

The mainscan image size is too large for the drum (note that the plate size is not checked). The maximum image size is specified in "set sys maxis". This parameter should be at default.

The workstation sends the mainscan image size for each image that it initiates (except for series type plots, these might be handled like diagnostic monitor plots).

If this error occured with a diagnostic monitor plot, modify the image size in the "set mode <mode> mis" parameter (units of DPI).


Operator Action:

Record error message and contact Creo Service


Cause:

  • "set mode <mode> mis" parameter too large for drum diameter with diagnostic monitor plot
  • Imposition error (image rotated?)
  • "set sys maxis" parameter incorrect

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page