Error Number: 16029


Error Message:

IMAGE: Failures detected when verifying SGE scan data


Applies to:

  • Green

Service Information:

This error indicates a problem has been detected with the ECL memory on the SGE. The ECL power supplies (-5.2V and +4.6V) should be checked at the test points on the SGE. If these are within spec, reseat the SGE. If the error persists, replace the SGE.


Operator Action:

Record error message and contact Creo Service


Cause:

  • ECL power supplies out of spec
  • SGE improperly seated
  • SGE faulty

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:49 2002 PST