Error Number: 16032


Error Message:

IMAGE: Requested SGE table is not yet defined


Applies to:

  • Green

Service Information:

An attempt has been made to use a stroke in a mode that has not yet been properly initialized. If a new mode has been defined, this mode should be saved and the recorder reset. If the recorder has just started up, wait until the recorder has indicated that it has finished initializing both scan tables.


Operator Action:

Record error message and contact Creo Service


Cause:

  • Stroke command issued before recorder properly initialized.
  • High resolution mode newly defined and recorder not reset.
  • Firmware bug.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:49 2002 PST