Error Message: |
IMAGE: Proofing donor already loaded |
Applies to: |
|
Service Information: |
The recorder received an image command for a proof but there is no receiver loaded on the drum. |
Operator Action: |
The workstation has launched a proof but the recorder has detected that there is already a receiver and donor on the drum by testing the plate_loc d proofer_status flag. When this flag is 3, the recorder thinks there is a donor on the drum. The workstation should have unloaded it at the end of the last proof by issuing a WORKSTATION_PROOF_END command but for some reason it didn't. If there is a donor on the drum, try to unload it from the workstation. If there is not a donor on the drum this error is possibly a firmware bug. Manually reset the flag. "set state plate_loc d proofer_status 0" Get the monitor log and report it to the responsible firmware developer. |
Cause:
|
See Also: |
|
Go to CTP Firmware Error Index Page