Error Number: 16050


Error Message:

IMAGE: DPE orthog slope less than 0, check plate rotation


Applies to:

  • All

Service Information:

The rotation needed to correct for the registration pin placements is too large. Check that the "set gc prot", "set gc sprot" and the "set gc ortho" parameters are at their factory settings (refer to the NVS configuration record). If they are, and this error is still reported, a firmware bug may be responsible.

If this error is reported while performing Trendsetter geometric correction, the placement of the small plate registration pin may be out of spec.


Operator Action:

Record error message and call Creo Service.


Cause:

  • NVS "set gc prot", "set gc sprot" or "set gc ortho" parameters changed from factory settings.
  • Trendsetter small plate registration pin placement out of spec.
  • Firmware bug.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:49 2002 PST