Error Number: 17015


Error Message:

HEAD: did not signal end of initialization


Applies to:

  • All

Service Information:

The head is not initializing properly. The head may be faulty, or its parameters may not be setup properly. The exposure head to backplane (EH-BP) cable should be checked. The exposure head's digital board should also be checked (parameters stored in EEPROM must be restored if the board is swapped). Check that the board has +5V.


Operator Action:

Reboot the Platesetter. Record error message and contact Creo Service


Cause:

  • Head parameters not setup correctly
  • Faulty EH-BP (exposure head to backplane) cable
  • Exposure head digital board faulty or not mounted correctly
  • Faulty head

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:50 2002 PST