Error Number: 17658


Error Message:

HEAD: DTD temperature below setpoint


Applies to:

  • Thermal

Service Information:

The measured temperature of the laser diode is below the setpoint value of 20 C (20W head) or 25 C (40 W head). Problem is either transient or there is a serious problem with the laser driver (DTD/WLC) or head controller board.


Operator Action:

Turn off machine and wait for laser to warm up and then try again. If still not OK call service.


Cause:

  • Laser diode temperature is too low.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:52 2002 PST