Error Number: 17671


Error Message:

HEAD: SCORR out of range


Applies to:

  • Thermal

Service Information:

The valid range for SCORR is -32.767 to 32.767. The specified value was out of range. With thermal head firmware versions greater than 1.5 neighbouring scorr table entries may not differ by more than 5% unless they are integer values. This is thus a better test for corrupt scorr tables.


Operator Action:

Call service. The head was not setup properly.


Cause:

  • Uninitialized or illegal Head scorr tables cause this error.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:52 2002 PST