Error Number: 17700


Error Message:

HEAD: Only the safety loop detected by the head has closed


Applies to:

  • Thermal

Service Information:

The write laser safety interlock switch, detected by the WLC, is not closed, although the focus laser interlock, detected by the HC, is closed. This is probably due to a problem with the interlock switch mechanism.

This error code applies to Thermal Head firmware version 1.34 and above.


Operator Action:

Ensure that all safety interlock switches are properly closed.


Cause:

  • A problem with the interlock switch mechanism.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:53 2002 PST