Error Number: 17736


Error Message:

HEAD: case temperature high warning, <temperature> C


Applies to:

  • Thermal

Service Information:

Every thirty seconds, the thermal head firmware reads the case temperature and compares the reading to a threshhold.

For air-cooled thermal heads ( either head NVS parameter casehigh or caselow is zero; but not both ), the threshhold is hardcoded to 45 degrees C. If the threshhold has been exceeded, this error message is provided for informational purposes only.

For water-cooled thermal heads ( neither head NVS parameter casehigh or caselow is zero ), the threshhold is determined by the NVS parameter casehigh. If the threshhold has been exceeded, this error message is provided to enable the chiller and for informational purposes.

This error code applies to Thermal Head firmware version 1.30 and above.


Operator Action:

No action is required; this message is for informational purposes only.


Cause:

  • The thermal head is getting warm.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page