Error Number: 18012


Error Message:

LASER: Communications error: No response


Applies to:

  • Green

Service Information:

The recorder should be reset. If this does not help, check that the red LED is lit on the laser power supply. If it isn't, check the power supply's cables and fuse. Check that AC is being supplied. If not, suspect the relay on the power distribution board.

If the power supply appears ok, the cable from the laser power supply to the laser controller should be checked. The serial cable from the laser to the backplane should be inspected and replaced if not loose.

Since the only other option is to replace the laser, the MPE should be replaced first. If this doesn't help, this error is likely due to a faulty laser controller. Note that the controller and the laser are matched and therefore the controller cannot be replaced without replacing the laser.


Operator Action:

Reboot the Platesetter. Contact Creo Service if rebooting does not help.


Cause:

  • Laser serial cable loose or faulty
  • Laser power supply faulty or fuse blown
  • Laser confused
  • Faulty MPE
  • Laser power supply to laser controller cable loose or faulty
  • Faulty laser controller

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:54 2002 PST