Error Number: 22001


Error Message:

ALE2: Flash cover door is not closed


Applies to:

  • ThermoFlex

Service Information:

This error is reported is the flash cover is found to not be closed at the beginning of an unload. To check sensor status, use the 'flashcvr' command.


Operator Action:

Close the flash cover, select resume.


Cause:

  • At the beginning of an unload, the flash cover should still be locked shut after the image that presumably occured beforehand. The firmware actually checks to see if the flash cover is closed and if not it reports this error. There could also be a problem with the flash cover sensors, however unlikely.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:54 2002 PST