Error Number: 22003


Error Message:

ALE2: No Plate sensed on table, nothing to load!


Applies to:

  • ThermoFlex

Service Information:

Check the table plate sensor to make sure it is plugged in and functional. Use the 'table' command to query the plate sensor status, tape or your hand will simulate a plate.


Operator Action:

Make sure plate edge is straight and covers the table plate sensor when loading.


Cause:

  • In a load situation, the first push of the START button is to activate the vacuum on the drum. The firmware looks to see if there is a plate present or not before it actually activates the vacuum. In this case it failed to see a plate on the table and it's complaining.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:54 2002 PST