Error Number: 22015


Error Message:

ALE2: ALE board still in reset


Applies to:

  • ThermoFlex

Service Information:

The ALE board has been reset for some reason. Confirm proper operation of the ale board. Re-seat the board (with the power off) and reset the ThermoFlex. Watch for error messages as the ALE LCA file is downloaded during the startup sequence. Check the power supplies to the ALE. Look for causes of static discharge which may have reset the ALE board. Replace ALE board if no cause for the problem is found, and return the ALE board to system engineer for diagnosis.


Operator Action:

This is not an operator-serviceable error. Call Creo response to log the error. Reset the machine to continue production.


Cause:

  • The ALE_RESET bit of the ale.version register has been set for some reason.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:55 2002 PST