Error Number: 22030


Error Message:

ALE2: Plate not detected by the table's plate sensor


Applies to:

  • ThermoFlex

Service Information:

Check the sensor - use the 'table' command to poll the sensor. Verify that the plate being used isn't cut with a sharp angle possibly uncovering the sensor.


Operator Action:

Make sure a plate has been properly registered and attached at the Leading edge.


Cause:

  • The machine didn't detect a plate on the table when it should have. This check for a plate is done just before rotating the drum to load a plate so there should be plate registered on the drums LE bar. Given the smallest acceptable plate, the sensor should be covered but doesn't seem to be.

See Also: