Error Number: 22093


Error Message:

ALE2: Possible defect in imaging surface, check plot for artifacts when done


Applies to:

  • ThermoFlex

Service Information:

When the head stage finishes zeroing, it checks 3 more positions on the plate by rotating the drum. At each position it measures the focus error, if one or more of the focus error values are really high then this error will be reported. The main cause for this is a bubble in the loaded media although its possibly due to somethine trapped beneath the media as well.


Operator Action:

Resume or cancel and reload.


Cause:

  • Probably a bubble in the loaded media. Error value fluctuations measured by head stage are too large.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:56 2002 PST