Error Number: 22107


Error Message:

ALE2: Drum Vacuum Pressure to low to hold plate - please check vacuum system.


Applies to:

  • ThermoFlex

Service Information:

Check the sensor calibration: Perform a drumvac cal and see if the problem goes away. Check that internal sensing lines are connected and not leaking.


Operator Action:

Verify that pump is on and hose is connected to machine. Call for Service.


Cause:

  • The level of suction in the drum is below the setpoint required to load the plate. This can be caused by a number of things: - Sensor mis-calibrated - Sensing tube disconnected - Vacuum pump hose disconnected - Power lost at vacuum pump

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:56 2002 PST