Error Number: 22250


Error Message:

ALE2: Slipsheet rollers may be open when trying to move the picker over them


Applies to:

  • Trendsetter_VLF_Auto

Service Information:


Operator Action:


Cause:

  • There is no slipsheet roller closed sensor (yet) but if the close output. bit is not driving it closed and the open output bit readback is driving it open then it's probably open.

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:01:57 2002 PST