Error Number: 23327


Error Message:

SCON: Stepper Motor %u driver under voltage fault detected


Applies to:

  • Trendsetter_VLF_Auto

Service Information:

Check voltage in on 48V on J1-1 & J1-2, +12V in on J1-5, and -12V in on J1-4. The status is on TP6 (high=fault low=ok). You can read the 24 and 48 V as read by each genine by typing 'ale'.


Operator Action:


Cause:

  • Remote stepper driver under voltage fault was detected. The under voltage fault signal is the combination of +12 low, or -12 low or the 48 V low, as read by on the Carriage board (10-3761B) and passed as a digital status signal to the Genine. Variable: <%u> - motor number

See Also:


Go to CTP Firmware Error Index Page

Go to CTP Firmware Error Search Page

Go to CTP Firmware Main Page


Creo CTP F/W Error Code Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:02:00 2002 PST