NVS Parameter: al nlr


Long Name:

no_load_ramp_sensor

Applies to:

  • Platesetter_3244

  • Description:

    Disables checking of the load ramp position sensor.

    • nlr = 0 enables checking of sensor.
    • nlr = 1 disables checking of sensor.


    Type:

    integer

    Default:

    • 1

    Range:

    • 0 to 1

    Notes:

    Disabling this sensor is dangerous as the load ramp could be in the no-fly zone of the drum and the firmware will not check it, before attempting to spin the drum.


    Partition:

    cal

    See Also:

  • NVS: al lr
  • Other: Platesetter Acronyms and Definitions

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:10 2002 PST