NVS Parameter: al nus


Long Name:

no_unload_sensor

Applies to:

  • Platesetter_3244

  • Description:

    This disables the sensors on the cylinder which lifts the plate up the unload from table from the drum, and then ejects it after the table is lowered (see no_table_sensor and

    • nus = 0 enables checking of sensor.
    • nus = 1 disables checking of sensor.


    Type:

    integer

    Default:

    • 0

    Range:

    • 0 to 1

    Notes:

    When the sensors are disabled (nus=1) then the firmware defaults to delay of (unload_delay) milliseconds before it assumes the cylinder moved as directed. When enabled (nus=0) the same amount of time is allowed for the appropriate sensor to be detected before a timeout error is generated.


    Partition:

    cal

    See Also:

  • NVS: aldly uldly
  • NVS: al nts
  • Other: Platesetter Acronyms and Definitions

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:11 2002 PST