NVS Parameter: al dvt


Long Name:

drum_vacuum_threshold

Applies to:

  • ThermoFlex

  • Description:

    This value, once set in psi with a single decimal point sets the minimum drum vacuum required for successful imaging. If the vacuum should not meet or exceed this value, an error will occur causing any imaging in progress to be aborted. This parameter is only referenced while the value check_drum_vacuum under state al is set to 1.

    ** Currently the default is set to zero because some machines are not equipped with the required pressure sensing hardware.

    ** This applies only to ThermoFlex Version 1.00 and lower - all future releases (1.10 and up) have a set point under media.


    Type:

    int32

    Default:

    • 0L

    Range:

    • 0L to 150L [psi]

    Notes:


    Partition:

    cfg

    See Also:

  • NVS: al mdv

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:13 2002 PST