NVS Parameter: state al lpe


Long Name:

lost_plate_errors

Applies to:

  • Trendsetter_400/800_Auto
  • Trendsetter_NEWS

  • Description:

    This parameter keeps track of how often the version 3 picker loses the plate while wristing out. This may happen if the plates are sticking together. If, after the picker wrist has finished moving out, the vacuum level is below threshold, then this parameter will be incremented. The picker will then attempt to grab the plate again before suspending with an error. If the device does suspend with an error, this parameter will have been incremented twice.

    This situation can only be detected with a version 3 picker.

    This parameter is updated automatically when an error occurs. It should not be changed.


    Type:

    uint16

    Default:

    • 0

    Range:

    • 0 to 65535

    Notes:

    Only supported in firmware versions 1.40 and above.


    Partition:

    state

    See Also:

  • Command: pick
  • Command: picker
  • NVS: al vpi
  • Error: E_ALE_PLATES_STICKING_TOGETHER

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page