NVS Parameter: aldly lrio


Long Name:

load_ramp_in_out

Applies to:

  • Trendsetter_400/800_Auto
  • Trendsetter_NEWS

  • Description:

    This value specifies the maximum time to wait when moving the load ramp actuators. There are sensors for the away-from-the drum position only. If these are enabled, the system will wait until either the sensors are activated or this amount of time has expired. If the sensors are enabled and the time has expired, the system will suspend with an error message. If the sensors are disabled or when the load ramp is being moved towards the drum, the system will wait for the full amount of time specified by this parameter.


    Type:

    uint32

    Default:

    • 1

    Range:

    • 0 to 60 [seconds]

    Notes:


    Partition:

    cal

    See Also:

  • NVS: al lrs

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:18 2002 PST