NVS Parameter: al lrs


Long Name:

load_ramp_sensor

Applies to:

  • Trendsetter_400/800_Auto
  • Trendsetter_NEWS

  • Description:

    When set, (1), this flag enables the top and bottom load ramp out (AWAY from drum) sensors. These sensors are also used to verify that the load ramp actuators have successfully moved to the desired location and to ensure that the load ramp is not in the "no fly" zone before spinning the drum. When cleared, (0), the sensor is by-passed and timeouts are used instead.


    Type:

    byte

    Default:

    • 1

    Range:

    • 0 to 1

    Notes:

    If this flag is cleared, (0), machine operation is significantly slowed down and some critical safety checks are not done. Clearing this flag should only be done on a temporary basis and the sensor should be repaired as soon as possible. Please do not clear this flag unless absolutely necessary!


    Partition:

    cal

    See Also:

  • Command: ramp
  • NVS: aldly lrio
  • NVS: aldly lrp

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:10 2002 PST