NVS Parameter: aldly pio


Long Name:

picker_in_out

Applies to:

  • Trendsetter_400/800_Auto
  • Trendsetter_NEWS

  • Description:

    This value specifies the maximum time to wait when moving the picker in or out. There are sensors for the picker out (away from the plate stack) position only. If these are enabled, the system will wait until either the sensors are activated or this amount of time has expired. If the sensors are enabled and the time has expired, the system will suspend with an error message. If the sensors are disabled or when the picker is being moved towards the plates, the system will wait for the full amount of time specified by this parameter.

    For the version 3 picker, the aldly phid parameter is used when moving the head in towards the plate stack.


    Type:

    uint32

    Default:

    • 50

    Range:

    • 0 to 60 [seconds]

    Notes:


    Partition:

    cal

    See Also:

  • NVS: al pios
  • NVS: aldly phid
  • NVS: al vpi

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:18 2002 PST